YM-2 Kev Ntsuas Range 0.96-2.5 Mud Balance
I.Function
YM-2 Mud Balance is used to determine specific gravity of mud,and it's unit i g/cm³.
II.Basic parameter
Measuring range:0.96-2.5 g/cm³(type YM-2)
Graduation: 0.01 g/cm3 Mud cup volume∶ 140 g/cm² Instrument structure
Hom YM av Liquid Densimeter yog hom caj npab tsis sib npaug qib ntsuas.Cov qauv qhia raws li daim duab hauv qab no.
mud khob cap; kab rov tav vesicle lub ntsiab hau hniav; hnyav; plug; av nkos khob; lub ntsiab hniav qhov tsua ntawm adminicula; tshuaj noj; tshuav nyiaj li cas.
It has a main lever ruler,and a cap blade in the ruler is used as pivot.There is a mud cup with a cap on the left of main lever ruler,and there is a balance bucket witha plug on the right of main lever ruler, the plug is mainly used for rectifying the heavy(lead buttons) which is needed by the balance of lever. Consequently, do not unscrew the plug unless rectifying the instrument. There is a horizontal vesicle on the main lever above the main blade,and it shows that the lever is in a balanced situation when the horizontal vesicle is on the middle position. There is a mobilizable weight on the lever. The screw on the back of weight is used to make the weight remove smoothly on the lever groove. There is a tapped hole on the weight bottom which is used to adjust the weight's weight. Do not unscrew this tapped hole in case inaccuracy of instrument. The main lever ruler is put on the cave of adminicula,so,the ruler can sways flexibly.A support is designed on the adminicula in order to prevent the man ruler over slanted, and the main ruler can rest on this support when the instrument is not on work.
III. Cov cai tswj kev ua haujlwm
1. Tshem tawm ntawm lub khob av nkos, ua kom tiav lub khob nrog cov av nkos los ntsuas.Yog tias muaj npuas hauv av, khob av nkos maj mam kom txog thaum nws npuas dej hla lub khob (coj av nkos rau 25 zaug yog tias av nkos yog cement.
2. Muab lub hau rau ntawm lub khob av nkos, ntsia hlau kom nruj li sai tau kom cov av nkos thiab cua extruded los ntawm cov pores me me nyob rau hauv nruab nrab ntawm lub hau.
3. So cov av nkos ntawm lub hau thiab lub zog.
4. Muab lub hau npog rau ntawm lub qhov tsua ntawm adminicula, nrog rau tus pas ntsuas lub ntsiab so ntawm kev txhawb nqa.
5. Txav qhov hnyav ze rau lub ntsiab hniav, ces txav qhov hnyav maj mam mus rau sab xis thiaj li ua kom tus pas ntsuas lub ntsiab sib npaug (nws tuaj yeem kuaj xyuas seb lub vesicle kab rov tav nyob nruab nrab).
6.Reading naj npawb: tus zuam cim coj mus rau sab laug sideline ntawm qhov hnyav yog qhov tshwj xeeb nqus av nkos ntsuas.