PHS-2F Tus Nqi Zoo Tshaj Plaws Tshaj Plaws pH Meter
PHS-2F Benchtop pH Meter
Taw qhia
Nco ntsoov cov teeb meem hauv qab no thaum siv:
l Xyuas kom muaj av zoo.
l Tiv thaiv corrosive gas ntxeem tau.
l Khaws lub ntsuas ntsuas kom huv, qhuav, thiab tsis txhob sib cuag nrog kua qaub, alkali, ntsev tov.
l Cov cuab yeej no muaj rau kev siv sijhawm ntev -. Tom qab kuaj cov qauv, cov electrode yuav tsum tau muab tso rau hauv DI dej.
l Keep the instrument interface clean, dry, and avoid contact with acid, alkali, salt solution. Insert short circuit when the instrument is not in use to avoid open circuit damage.
Cov ntsiab lus
pH nqes hav: Qhov muaj peev xwm hloov pauv rau txhua qhov kev hloov pauv pH, feem ntau qhia tias mV / pH lossis feem pua.
pH E0: Also called "zero potential", usually refers to the potential value of the pH=7.
pH ib -point calibration: Calibrate nrog ib tug pH buffer tov.
pH multi-point calibration: Calibrate nrog ob los yog ntau tshaj pH buffer tov.
Nta
l Txais cov qauv tsim tshiab, loj LCD segmented zaub.
l Nws yog tsuas yog siv los ntsuas pH tus nqi thiab muaj peev xwm tus nqi (mV) ntawm kev daws dej hauv thaj chaw tshawb fawb, kev lag luam, mining lag luam, tsev kawm qib siab thiab tsev kawm qib siab. Tsis tas li ntawd, nws tseem tuaj yeem ntsuas qhov muaj peev xwm electrode thaum sib txuam nrog ion xaiv electrode
Main kev ua tau zoo
1. Kev ntsuas ntau
a. pH:(0.00-14.00)pH;
b. mV:-1400mV-1400mV;
2. Yam tsawg kawg nkaus tso saib: 0.01pH, 1Mv
3. Kub them nyiaj ntau: Phau ntawv (060) degree
4. Electronic unit raug
a. pH: ±0.01pH;
b. mV:±0.1 percent FS
5. Accuracy of meter: ±0.02pH±1bit;
6. Cov tswv yim tam sim no ntawm chav tsev hluav taws xob: Tsawg dua lossis sib npaug ntawm 110-12A
7. Input impedance of electronic unit: Greater than or equal to l1012Ω
8. Error of temperature compensation: ±0.01 pH
9. Repeatability yuam kev ntawm chav tsev hluav taws xob:
pH: 0.01 pH
mV: 1 mv
1 0. Repeatability yuam kev ntawm 'meter': Tsawg dua los yog sib npaug rau 0.01pH
11. Repeatability of electronic unit: 0.01 pH±l bit/3h
12. Loj: (ntev dav qhov siab, mm): 29021095
13. Nyhav, kg: 1.5 kg
14. Cov xwm txheej ua haujlwm li qub:
a) ambient kub: (5-40) degree;
b) Relative humidity: Less than or equal to 85%;
c) Fais fab mov: 220V 50Hz
d) Tsis muaj kev vibration uas cuam tshuam rau kev ua haujlwm nyob ze.
e) Tsis muaj corrosive gas nyob ze.
Tsis muaj kev cuam tshuam magnetic tsuas yog teb.



Cim npe nrov: PHS-2F Tus Nqi Zoo Tshaj Plaws Phem Phem Meter, Tuam Tshoj, cov chaw muag khoom, chaw tsim khoom, nqe, kev muag, Benchtop pH Meter, digital ph meter rau dej, handheld digital ph meter, zoo tshaj plaws benchtop ph meter rau kev siv, benchtop ph tester PHS- 2F, kuaj portable bench sab saum toj ph meter, benchtopphmeter, phmeterdigital, phmv meter, tes tuav portable ph meter, ph meter nrog electrode, tabletop ph meter, ph meter rooj hom
Xa kev nug