HZSD-29B ASTM D287 API Thiab Cov txheeb ze ntom ntom Specific Gravity Tester
I, Product Description
Raws li GB / t13531, ASTM d287 thiab lwm yam specifications. Txoj kev buoyancy ntawm Archimedes txoj cai yog siv los nyeem sai sai API qhov tseem ceeb ntawm tus txheeb ze ntom ntom ntom ntom ntom ntom ntom ntom ntom ntom ntom ntom ntom ntawm cov khoom siv roj.
II, API coefficient Description
nws hais txog tus coefficient ntawm txheeb ze qhov ceev hloov pauv API. Cov txheeb ze ntom ntom ntawm cov kua thiab API tsis tuaj yeem qhia qhov tseeb kev sib raug zoo, tab sis ib qho kev sib raug zoo nkhaus. Cov cuab yeej siv qhov tshwj xeeb 4-point nkhaus algorithm los hloov cov txheeb ze ntawm ntau cov kua rau API. 4-point nkhaus algorithm muaj qhov raug siab dua li 2-point linear algorithm. Raws li qhov sib txawv ntawm qhov kub thiab txias, tus txheeb ze hloov pauv qhov sib txawv API coefficients ntawm tib cov kua sib txawv. Cov cuab yeej muaj built-in ntau pab pawg ntawm cov khoom siv roj (petroleum, crude roj, glycerol, lubricating roj, thiab lwm yam) Concentration conversion coefficient ntawm tsis kub.
III, Digital zaub ncaj qha nyeem ntawv
txheeb ze ntom ntom (specific gravity), tshwj xeeb gravity API, concentration... Thiab lwm yam tsis.
IV, Cov kua dej siv tau
petroleum, roj av, thiab lwm yam.
V, Khoom nta
Kov ua haujlwm, ib qho tseem ceeb xaiv ntawm roj av API tus nqi, tsis muaj cumbersome teeb tsa cov kauj ruam, lub lag luam yog yooj yim thiab yooj yim to taub;
The unique multi{{0}}point curve concentration measurement algorithm is used to test the API of various oil products (such as crude oil, petroleum, lubricating oil, etc.), and the API accuracy can reach ± 0.1 percent . Compared with the common two-point linear API measurement algorithm in the market, the multi-point curve API algorithm has higher accuracy;
Qhov ua tau - nyob rau hauv qhov kub thiab txias qhov chaw them nyiaj ua haujlwm tuaj yeem teeb tsa tus nqi kub ntawm cov roj crude kom ntsuas tau sai. Cov khoom siv thermostatic mam-hw-1008 kuj raug xaiv los ntsuas qhov ntom / concentration / Baume tus nqi ntawm cov roj crude ntawm qhov kub thiab txias (xws li 25 degree );
Lub cuab yeej ua haujlwm los ntawm microcomputer kov npo, thiab qhov ntsuas qhov ntsuas hauv Suav thiab Askiv tau pom meej meej; Thiab txhua kauj ruam ua haujlwm tuaj yeem thim rov qab (piv txwv li, yog tias koj pom qhov teeb meem hauv ib kauj ruam ua haujlwm, koj tuaj yeem rov qab mus rau kauj ruam thiab ua haujlwm dua yam tsis tau pib los ntawm kos);
Nruab nrog tiv thaiv {{0}}corrosion thiab kub accessories, nws yog haum rau feem ntau cov kua thiab 0 consumables nyob rau hauv cov txheej txheem siv.
VI, Technical parameter
Qauv | HZSD-29B |
Max load | 150g |
AIP Scope | 0.01100.00 degree |
API raug | 0.01 degree API |
Kub tiv taus ntau yam | -20270 degree |
ntsuas txoj cai | Hloov txoj kev ntawm Archimedes txoj cai |
Kub them nyiaj ntau yam | 0-110 degree |
Lub sijhawm ntsuas | 5 vib nas this |
Cov txiaj ntsig qhia tau tias | Ceev, API degree |
Qhov ceev / concentration daws teeb meem ntau | 0.00199.999g/cm ³ / 0.01 percent 100 percent |
muab hluav taws xob | AC100V240V 50HZ/60HZ |



Cim npe nrov: HZSD-29B ASTM D287 API Thiab Tus txheeb ze Ceev Cov Kev Ntsuas Ntsuas Ntsuas, Tuam Tshoj, lwm tus neeg, manufacturers, nqe, kev muag, api hydrometer
Xa kev nug