HZ-1011P 3 Theem Hluav Taws Xob Hluav Taws Xob Meter Calibration Kit
I. Txheej txheem cej luam
Multi-function electric energy meter on-site testing instrument is a high precision testing instrument that can measure electrical parameter and verify electric energy meter and judge on-site wiring. The instrument is equipped with the high precision and high linearity PT and CT ,so it has the high measuring accuracy when testing various electrical parameters.And it is equipped with the clamp-type current transformers . Users don't need to disconnect the current circuit to wire easily with them on site .The instrument uses high-end embedded control panel and dedicated real-time multitasking operating system and 10-inch large-screen color LCD monitor . It uses English graphical operation interface with English prompt information. The man-machine dialogue interface is friendly .It has the functions of vector diagram display and wiring judgment ,which can provide the reliable basis for checking the correctness of the circuit. It uses the capacitive screen touch operation which is good handing feel and easy to learn. It has built-in large-capacity data memory, which can store a maximum of 60,000 groups of data and can be extended indefinitely.Users can upload the history-records to the computer with the U disk and can also use the background management software of the instrument to achieve the computerized management.
The instrument is made of engineering plastic shell designed and moulded independently by our company. The instrument is beautiful in appearance and practical. It is easy to operate while testing on site. When the instrument is operated, its back bracket can be opened. So it can be operated by hand or on the desktop. The instrument is equipped with high strength self-stretching handle. It is convenient for the operator to hold the instrument with one hand.
II.Technical Specifications
1.Input zog
Kev ntsuas voltage:
0 400V, 57.7V, 100V, 220V, 400V plaub tsis siv neeg hloov ntau yam.
Kev ntsuas tam sim no:
05a ib. Cov ua tau - tam sim no transformers yog 5A (CT).
Lub clamp transformer muaj rau kais txoj hauj lwm:
me me clamp (5A / 25A).
nruab nrab clamp (100A / 500A) (yeem).
loj clamp (400A / 2000A).(yeem).
Lub kaum sab xis ntsuas ntau: 0 359.999 degree.
Kev ntsuas ntau zaus: 45 55 Hz.
2. Qhov tseeb
Kev ntsuas ntsuas qhov ntsuas:
Voltage: ± 0.05 percent
Current: ± {{0}}.05 percent (clamp transformer ± 0.2 percent )
Active power: ± {{0}}.05 percent (clamp transformer ± 0.2 percent )
Reactive power: ± {{0}}.2 percent (clamp transformer ± 0.5 percent )
Active electric energy: ± {{0}}.05 percent (clamp transformer ± 0.2 percent )
Reactive electric energy: ± {{0}}.2 percent (clamp transformer ± 0.5 percent )
Frequency: ± 0.05 percent
Phase: ± 0.2 degree
3. Lub zog zoo
Harmonic zaus ntsuas ntau: 2-64
Qhov tseem ceeb voltage thiab tam sim no amplitude: tso cai yuam kev ntawm lub hauv paus voltage Tsawg dua los yog sib npaug rau 0.5 feem pua FS; Kev tso cai yuam kev ntawm qhov tseem ceeb tam sim no Tsawg dua lossis sib npaug li 1 feem pua FS
Kev ntsuas yuam kev ntawm theem sib txawv ntawm qhov tseem ceeb voltage thiab tam sim no:
Tsawg dua lossis sib npaug rau 0.5 degree
Kev ntsuas yuam kev ntawm cov ntsiab lus ntawm qhov sib haum xeeb: Tsawg dua lossis sib npaug rau 0.1 feem pua
Kev ntsuas yuam kev ntawm cov ntsiab lus tam sim no sib haum xeeb: Tsawg dua lossis sib npaug rau 0.2 feem pua
Peb theem voltage unbalance yuam kev: Tsawg dua los yog sib npaug rau 0.2 feem pua
4. Ua haujlwm kub
Kev khiav hauj lwm kub: -10 degree ntxiv rau 40 degree
5. Rwb thaiv tsev
1) The insulation resistance between the voltage, current input terminal and the housing Greater than or equal to 100MΩ.
2) Nrog rau 1.5KV (tus nqi siv tau) nrog lub zog zaus ntawm kev khiav hauj lwm lub zog tawm tswv yim thiab lub plhaub, uas kav ib feeb.
6. Txheem hluav taws xob hluav taws xob mem tes tas li
built-in transformer constant (FL) = 10000 r / kW · h
Clamp transformer tsis tu ncua (FL):
5A | 25A | 100A | 500A | 400A | 2000A |
10000r/kW·h | 2000r/kW·h | 500r/kW·h | 100r/kW·h | 125 r/kW·h | 25r/kW·h |
7. Nyhav
Luj: 2 kg
8. Loj
Loj: 28cm 21cm 6cm
Cim npe nrov: HZ-1011P 3 Theem Hluav Taws Xob Hluav Taws Xob Meter Calibration Kit, Tuam Tshoj, lwm tus neeg, manufacturers, nqe, kev muag khoom, siab precision zog ntsuas calibration